GO
SEARCH:
Back

Fault Codes

GE "New-'99" Range/Stove/Oven Fault Codes

Failure
Code
Condition
Check/Repair
FFF
Control Error, Failed EEPROM
Replace Control
F0 or F7
Shorted Clear/Off Key due to membrane switch, control or connector
Shorted key panel membrane switch; Check Electronic Range Control (ERC)
F2 During Bake
Control senses oven temp above 590 degrees F
High resistance connection in oven temperature sensor circuit. Check Electronic Range Control (ERC) - Welded bake relay contacts
F2 During Clean
Control senses oven temp above 915 degrees F
High resistance connection in oven temperature sensor circuit. Check Electronic Range Control (ERC) - Welded clean relay contacts. Both lock switch 1 & 2 closed at the same time
F3
Open oven temperature sensor, oven temperature sensor resistance exceeds 2900 ohms during bake, broil or clean
Oven temperature sensor/Oven temperature sensor circuit connections
F4
Shorted oven temperature sensor, oven temperature sensor resistance less than 2900 ohms during bake, broil or clean
Oven temperature sensor/oven temperature sensor circuit connections
FFF
Door motor safety circuit
Electronic Range Control (ERC)