The 3 most common part(s) or condition(s) which cause the symptom Dryer trips breaker are listed below starting with the most likely. Check or test each item and watch any available videos.

Other Causes and Conditions

The Circuit Breaker is Weak

If the dryer trips the home's circuit breaker, the breaker itself might be defective. Over time circuit breakers can become weak and may trip often, even though the amperage draw is below the limit. If the dryer has been checked and seems to be fine, consider having an electrician replace the circuit breaker.

Grid is 1 inch square
Heating Element Assembly - Part # 1377645 Mfg Part # 5301EL1001J

Heating Element Assembly

RepairClinic Item # 1377645

When heating element assemblies fail, they sometimes short out against the heater housing. Then, the dryer trips the circuit breaker. If the circuit breaker is reset and it trips again, check the heating element assembly for a short circuit.

$87.30

Order now and this item will ship out tomorrow

Add to Cart

365 Day Return Policy

Grid is 1 inch square
Drive Motor - Part # 1330330 Mfg Part # 4681EL1008A

Drive Motor

RepairClinic Item # 1330330

Although not as common, if the dryer trips the circuit breaker the drive motor may be defective. When drive motors fail, they sometimes short out internally and trip the circuit breaker.