The 6 most common part(s) or condition(s) which contribute to the symptom Snowblower auger won't turn are listed below. Check or test each item and watch any available videos. If you are still unable to solve the problem you may need to do additional research and troubleshooting. Remember, with our 365 Days. Period.® return policy you can return any part for any reason. So, go ahead and buy it to try it. No other parts retailer offers this unconditional return policy.

For the symptom you selected, these are the most common parts or causes, ordered by the likelihood of fixing the symptom.

Grid is 1 inch square
Shear Bolt and Nut - Part # 1773118 Mfg Part # 53200500

Shear Bolt and Nut

RepairClinic Item # 1773118

If the snowblower auger won't turn the shear bolt and nut may have failed. The shear bolt is a metal bolt that slides through the auger axle sleeve to lock it in place with the auger drive axle. If the auger hits a rock or other object, the shear bolt is designed to cut in half and fall out in order to protect the auger, gearbox and other components. If the auger won't turn, check to see if the shear bolt is in place and intact. If not, replace it.

Place your order by 3:00 PM ET and choose FedEx 2Day or FedEx Overnight shipping and this item will ship out today - or it's FREE!

Grid is 1 inch square
Belt: V-Belt - Part # 1780408 Mfg Part # 07200101

Belt: V-Belt

RepairClinic Item # 1780408

If the snowblower auger won't turn the belt might be broken or worn out. A belt makes the connection between the engine and the auger, sometimes directly driving the auger and sometimes powering the auger through a gearbox. If the belt is worn out, misadjusted, or broken the auger won't turn.

Place your order by 3:00 PM ET and choose FedEx 2Day or FedEx Overnight shipping and this item will ship out today - or it's FREE!

Grid is 1 inch square
Belt: V-Belt - Part # 1780458 Mfg Part # 07200513

Belt: V-Belt

RepairClinic Item # 1780458

If the snowblower auger won't turn the belt might be broken or worn out. A belt makes the connection between the engine and the auger, sometimes directly driving the auger and sometimes powering the auger through a gearbox. If the belt is worn out, misadjusted, or broken the auger won't turn.

Place your order by 3:00 PM ET and choose FedEx 2Day or FedEx Overnight shipping and this item will ship out today - or it's FREE!

Picture Unavailable

Auger Assembly

RepairClinic Item # 1763634

If only one auger turns check the sheer pin in the one that is not turning. If the sheer pin is okay the problem may be in the gear case assembly.

Picture Unavailable

Auger Assembly

RepairClinic Item # 1763638

If only one auger turns check the sheer pin in the one that is not turning. If the sheer pin is okay the problem may be in the gear case assembly.

Grid is 1 inch square
Bearing - Part # 1763980 Mfg Part # 05406300

Bearing

RepairClinic Item # 1763980

If the auger won't turn one or more of the bearings might have seized. Most bearings are permanently lubricated and don't require maintenance. If yours has a grease fitting, fresh grease should be added according to the manufacturers instructions. Once the bearing seizes it will have to be replaced. Sometimes the bearing can be freed up to work temporarily, but that fix is usually temporary.