The 2 most common part(s) or condition(s) which contribute to the symptom Washer stops mid cycle are listed below. Check or test each item and watch any available videos. If you are still unable to solve the problem you may need to do additional research and troubleshooting. Remember, with our 365 Days. Period.® return policy you can return any part for any reason. So, go ahead and buy it to try it. No other parts retailer offers this unconditional return policy.

For the symptom you selected, these are the most common parts or causes, ordered by the likelihood of fixing the symptom.

Grid is 1 inch square
Water Inlet Valve - Part # 1475762 Mfg Part # WH13X10029

Water Inlet Valve

RepairClinic Item # 1475762

If the washer stops mid cycle the water inlet valve cold water side may have failed. Most washers have a cold water rinse and so if they can't fill with cold water they just sit indefinitely waiting for the cold water to enter. If there is cold water to the water inlet valve and the cold water works in other parts of the cycle - or to make warm water - the valve is not the problem.

Place your order by 8:00 PM ET and this item will ship out today - or it's FREE!

$69.80

Grid is 1 inch square
Main Control Board - Part # 1606332 Mfg Part # WH12X10468

Main Control Board

RepairClinic Item # 1606332

If the washer stops mid-cycle the main control board might be defective. This is not common. Check other causes first such as the lid or door switch and other components.