York Central Air Conditioning Replace Contactor S1-02427531000

loading...

02:42
28k
36
This video provides step-by-step instructions for replacing the contactor on York central air conditioning units. The most common reasons for replacing the contactor are when the condensing unit does not run, the air conditioner is noisy, or the air conditioner does not cool at all.

All of the information in this contactor replacement video is applicable to the following brands: York, Luxaire, Coleman

Tools used: multi-screwdriver, 5/16” socket, needle-nose pliers

Step By Step Instructions

1
To replace the contactor in your central air condensing unit first shut off the power to the unit.
2
You can do this by removing the fuses from the disconnect box or switching off the circuit breaker.
3
Use a 5/16th inch socket to unthread the screws securing the access cover and remove the cover.
4
Note the location of the wires connected to the old contactor – then disconnect them.
5
Next, remove the mounting screws to release the old contactor.
6
Install the new contactor by positioning it on the panel then replace the mounting screws to secure.
7
Connect the wires to the appropriate terminals on the new contactor.
8
Realign the access cover and replace the screws to secure.
9
With the repair completed, restore power to the condensing unit and your central air system should be ready for use.
Description
This video provides step-by-step instructions for replacing the contactor on York central air conditioning units. The most common reasons for replacing the contactor are when the condensing unit does not run, the air conditioner is noisy, or the air conditioner does not cool at all.

All of the information in this contactor replacement video is applicable to the following brands: York, Luxaire, Coleman

Tools used: multi-screwdriver, 5/16” socket, needle-nose pliers
Step-By-Step Instructions
1
To replace the contactor in your central air condensing unit first shut off the power to the unit.
2
You can do this by removing the fuses from the disconnect box or switching off the circuit breaker.
3
Use a 5/16th inch socket to unthread the screws securing the access cover and remove the cover.
4
Note the location of the wires connected to the old contactor – then disconnect them.
5
Next, remove the mounting screws to release the old contactor.
6
Install the new contactor by positioning it on the panel then replace the mounting screws to secure.
7
Connect the wires to the appropriate terminals on the new contactor.
8
Realign the access cover and replace the screws to secure.
9
With the repair completed, restore power to the condensing unit and your central air system should be ready for use.