Step By Step Instructions

1
To replace the pressure switch in your furnace first turn off the power to the furnace.
2
Slide the upper access panel up to remove.
3
Detach the vacuum tube from the old pressure switch. and disconnect the wires.
4
Use a flat-head screwdriver to unthread the screws securing the pressure switch mounting bracket.
5
Install the new pressure switch and bracket by positioning it on the frame.
6
Thread the screws to secure.
7
Connect the wires to the appropriate terminals on the new switch.
8
Attach the vacuum tube.
9
Replace the upper access panel.
10
With the repair completed, turn the power back on and your furnace should be ready for use.
Description
This video provides step-by-step instructions for replacing the pressure switch on Rheem furnaces. The most common reasons for replacing the switch are when the furnace does not heat or only runs for a few minutes.

All of the information in this pressure switch replacement video is applicable to the following brands: Rheem, Ruud, DuroGuard, WeatherKing

Tools used: flat-head screwdriver
Step-By-Step Instructions
1
To replace the pressure switch in your furnace first turn off the power to the furnace.
2
Slide the upper access panel up to remove.
3
Detach the vacuum tube from the old pressure switch. and disconnect the wires.
4
Use a flat-head screwdriver to unthread the screws securing the pressure switch mounting bracket.
5
Install the new pressure switch and bracket by positioning it on the frame.
6
Thread the screws to secure.
7
Connect the wires to the appropriate terminals on the new switch.
8
Attach the vacuum tube.
9
Replace the upper access panel.
10
With the repair completed, turn the power back on and your furnace should be ready for use.