Choose Product
Identify Problem
03
Find Solutions

Nutone Central air conditioner is noisy or loud

01 - Debris Hitting Fan
Over time debris can fall into the condensing unit, causing a noise when the fan is running. Inspect the fan blade and inside the unit for any debris. Clean out the condensing unit as needed.
02 - Panels Vibrating
If the outdoor condensing unit is noisy, the grille or one of the panels may be loose and vibrating. Check for loose panels and tighten them as needed.
03 - Nutone Central Air Conditioner Condenser Fan Motor
The condenser fan motor has bearings that can wear out over time. When the bearings are worn out, they make loud noise. To check the bearings, try rotating the condenser fan motor by hand. If the motor does not turn smoothly, replace it.
Required Part
Central Air Conditioner Condenser Fan Motor
Enter model number to search for the required part specific to your product
Common Solution
04 - Nutone Central Air Conditioner Fan Blade
The fan blade on the condenser fan motor might be defective or loose. To check the fan blade, wiggle the fan motor shaft. If the motor shaft is loose, tighten or replace the set screw. If the condenser fan motor is still making noise, replace the fan blade.
Required Part
Central Air Conditioner Fan Blade
Enter model number to search for the required part specific to your product
Common Solution
05 - Nutone Central Air Conditioner Contactor
The furnace control board sends a low voltage signal to the contactor. When the contactor receives the signal from the control board, it closes the circuit, sending voltage to the condensing unit components. If the contactor is defective, it will not provide voltage to the condensing unit. In addition, the contactor will make noise when it is defective. If the condensing unit is making noise but not cooling, the contactor has probably failed. To determine if the contactor is at fault, use a mult...imeter to test the contactor for continuity. If the contactor does not have continuity, replace it.
Required Part
Central Air Conditioner Contactor
Enter model number to search for the required part specific to your product
Common Solution
06 - Nutone Central Air Conditioner Compressor
The compressor pumps refrigerant through the central air conditioning unit. When the compressor is wearing out, it generates more noise than usual. When this happens, it is not necessary to replace the compressor—compressors often last for years after they become noisy. However, if you would prefer to have a new compressor, you must have a licensed professional replace it.
Required Part
Central Air Conditioner Compressor
Enter model number to search for the required part specific to your product
Common Solution