The part(s) or condition(s) listed below for the symptom Range burners spark all the time are ordered from most likely to least likely to occur. Check or test each item, starting with the items at the top of the page.

Most Frequent Causes for Range burners spark all the time

Cause 1Spark Ignition Switch

One of the spark ignition switches might be defective. The spark ignition switch sends voltage to the spark module. When the electrical contacts inside the switch close, power flows to the spark module. If the spark ignition switch fails with the electrical contacts closed, the switch will send continuous voltage to the spark module. To determine if any of the spark ignition switches is defective, use a multimeter to test each of the switches for continuity. If a spark ignition switches shows continuity at all settings, replace it.

Parts
Spark Ignition Switch for your GERange/Stove/Oven
Spark Ignition Switch - Part # 253066 Mfg Part # WB24K10003

Spark ignition switch, top burners. Switch has Gray hub and will spark at 7 O'clock. For switch that sparks at 11 O'clock position see related item.

Add to Cart
Cause 2Spark Module

The spark module provides power to each surface burner spark electrode. If the spark module fails, it may cause the burners to spark continuously. However, the spark ignition switch is more likely to be at fault. Before replacing the spark module, first test the spark ignition switch. If the spark ignition switch is working properly, consider replacing the spark module.

Parts
Spark Module for your GERange/Stove/Oven
Spark Module - Part # 244920 Mfg Part # WB13K25

Spark module for top burners. This spark module provides power to the spark electrode to produce a spark. If it is defective, the burner may not light.