2 Pole Contactor (60V, 10 Amp)
Grid is 1 inch square
  Contactor HN52PD024
  Contactor HN52PD024
  Contactor HN52PD024
  Contactor HN52PD024
  Contactor HN52PD024
  Contactor HN52PD024
  Contactor HN52PD024
  Contactor HN52PD024
Manufacturer Part

Contactor HN52PD024

Genuine OEM Part # HN52PD024RC Item # 2381386
Manufacturer Part
2 Pole Contactor (60V, 10 Amp)
Grid is 1 inch square
  Contactor HN52PD024
  Contactor HN52PD024
  Contactor HN52PD024
  Contactor HN52PD024
  Contactor HN52PD024
  Contactor HN52PD024
  Contactor HN52PD024
  Contactor HN52PD024
$135.01
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
2 Pole Contactor (60V, 10 Amp)
Loading stock status
$135.01

This part HN52PD024 is compatible with:

Product Type:
Air Conditioner, Heat Pump, Central Air Conditioner
Brands:
Bryant, Carrier, Payne

Related Articles & Videos

04:24
How This Part Works
Central Air Condensing Unit Contactor - How it Works & Installation Tips
03:12
Troubleshooting
Central Air Conditioner Not Cooling — Central Air Conditioner Troubleshooting
02:01
Troubleshooting
Air Conditioner Loud or Noisy — Air Conditioner Troubleshooting
03:57
Troubleshooting
Air Conditioner Fan Not Working — Air Conditioner Troubleshooting
Frequently Bought with Contactor
P291-4554RS Dual Run Capacitor
W10311524 Air Filter
LA660003 Fan Blade
WP694089 Blower Wheel

Contactor Customer Reviews

Common Problems Fixed by the Contactor

Based on customer reports and repair data, this part commonly fixes these issues:

Very Likely

Central air conditioner not cooling properly

Likely

Heat pump compressor won't run

Likely

Heat pump won't turn off

Likely

Heat pump not cooling

Likely

Heat pump not heating

Likely

Heat pump won't turn on

Likely

Central air conditioner compressor won't run

Possible

Central air conditioner won't turn off

Possible

Central air conditioner is noisy or loud

Possible

Heat pump is noisy or loud

Possible

Central Air Conditioner Condensing unit does not run

About the Contactor

The furnace control board sends a low voltage signal to the contactor. When the contactor receives the signal from the control board, it closes the circuit, sending voltage to the condensing unit components. If the contactor is defective, it will not provide voltage to the condensing unit. To determine if the contactor is at fault, use a multimeter to test the contactor for continuity. If the contactor does not have continuity, replace it.