Keep your Carrier 58MXA100-13116 furnace running efficiently with genuine OEM replacement parts from Repair Clinic. The 58MXA100-13116 is a 100,000 BTU input, 80% AFUE upflow gas furnace from Carrier. At 100,000 BTU this furnace cycles aggressively on cold days, accumulating igniter thermal cycles and inducer bearing hours faster per season than lower-output models. The furnace uses standard metal B-vent, produces no condensate, and has a straightforward non-condensing service profile. Repair Clinic stocks genuine Carrier OEM parts for the 58MXA100-13116 including the Carrier igniter parts, Carrier flame sensor parts, Carrier draft inducer motor parts, Carrier blower motor parts, and Carrier control board parts. Browse the Carrier furnace parts catalog filtered by 58MXA100-13116 for the complete parts inventory.
58MXA100-13116: Carrier 100,000 BTU Upflow Furnace Service
The Carrier 58MXA100-13116 is a non-condensing 80% AFUE upflow furnace at 100,000 BTU. At this output class the furnace cycles most aggressively on cold days. The 13116 configuration suffix should be confirmed from the data plate when ordering a replacement control board. Read the LED blink code before ordering any component. The Carrier furnace troubleshooting guide covers fault code blink patterns for the 58MXA platform control board.
Most Replaced Parts on the Carrier 58MXA100-13116
Igniter for the Carrier 58MXA100-13116
At 100,000 BTU the 58MXA100-13116 cycles aggressively, accumulating igniter thermal cycles faster per season than lower-output models. Testing resistance at room temperature confirms failure in under two minutes.
Carrier 58MXA100-13116 Flame Sensor
Annual cleaning with fine steel wool extends sensor service life and eliminates most early-season nuisance lockouts on the 58MXA platform.
Draft Inducer Motor for the 58MXA100-13116
At 100,000 BTU the inducer handles the greatest combustion gas volume in the 58MXA series. Bearing failure presents as grinding during the pre-purge phase at startup.
Carrier 58MXA100-13116 Control Board
Read and document the two-digit LED blink code before ordering any replacement. The 13116 suffix should be confirmed from the data plate before ordering a board.
Why Choose Repair Clinic for Carrier 58MXA100-13116 Parts
- Genuine Carrier OEM Components: Igniters, flame sensors, and inducers confirmed for the 58MXA100-13116 100,000 BTU upflow platform Carrier furnace parts.
- Fault Code Diagnostic Resources: The Carrier furnace troubleshooting LED blink code chart for the 58MXA platform is available alongside every part listing.
- Non-Condensing Service Profile: The 58MXA100-13116 uses standard B-vent and produces no condensate, distinguishing it from condensing Carrier models requiring PVC venting.
- 365-Day Returns: Return any uninstalled Carrier part within a full year of purchase with no restocking fees.
Carrier 58MXA100-13116 Furnace Parts FAQ
What is the BTU output and efficiency of the Carrier 58MXA100-13116?
The 58MXA100-13116 is a 100,000 BTU input, 80% AFUE upflow gas furnace. The 100 identifies 100,000 BTU capacity and the 13116 identifies the cabinet and production configuration.
What type of venting does the Carrier 58MXA100-13116 require?
Standard metal B-vent. It produces no condensate and does not use PVC venting.
My Carrier 58MXA100-13116 ignites and shuts off within seconds. What is wrong?
This is the flame sensor symptom. Annual cleaning with fine steel wool prevents most occurrences on the 58MXA platform.
How do I read the fault code on the Carrier 58MXA100-13116?
The control board LED flashes a two-digit blink code. Count the first group of flashes, note the pause, count the second group, and match to the chart inside the blower compartment door.