Lennox Furnace G26Q3-75-3 Parts

Shop replacement repair parts for Lennox Furnace model G26Q3-75-3

icons/furnace
Brand:Lennox
Model:G26Q3-75-3
Product:Furnace
55 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
22W78 Run Capacitor
$9.67

Run Capacitor. Single, Oval, 370 volt, 5 Microfarad.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
60L21 Blower Motor
$256.01

Furnace blower motor. This single-phase motor has the following specifications:

Horsepower: 1/3
Voltage: 115
Full-Load Amperage: 5.1
Hertz: 60
RPM: 1075
Speeds: 4
Rotation: Counterclockwise
Frame: 48
Enclosure: Open
Shaft Length: 4.25”

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
41K56 Igniter
$79.81

Furnace Igniter (80 volt) *** please see related item if 120 volt igniter is needed***

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
19V36 Control Board
$304.28

White-Rodgers 21D83M-843 Direct Replacement IFC Ignition Module The ignitiov control moduleregulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
40L81 Flame Sensor
$56.83

Flame sensor kit. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
42J32 Transformer
$29.56

Transformer, 120 Volt Primary 24 Volt Secondary 40 VA

Go

Keep your G26Q3-75-3 furnace running efficiently with genuine OEM replacement parts from Repair Clinic. The G26Q3-75-3 is a 75000 BTU input, 80% AFUE gas furnace from Lennox. The furnace uses standard metal B-vent, produces no condensate, and has a straightforward non-condensing service profile. The G26Q3 designation identifies an older Lennox 80% AFUE upflow furnace series. The 75 identifies 75,000 BTU capacity and 3 identifies the production revision. The igniter, flame sensor, standard metal B-vent, and control board account for the majority of service calls. Repair Clinic stocks genuine Lennox OEM parts for the G26Q3-75-3 including the Lennox igniter parts, Lennox flame sensor parts, Lennox draft inducer motor parts, and Lennox control board parts. Browse the Lennox furnace parts catalog filtered by G26Q3-75-3 for the complete parts inventory.

G26Q3-75-3: 75000 BTU, 80% AFUE Gas Furnace Service

Reading the control board LED blink code before ordering any component is the required first diagnostic step on the G26Q3-75-3. The blink code identifies the specific component fault. Annual flame sensor cleaning with fine steel wool prevents most nuisance lockouts. The Lennox furnace troubleshooting guide covers fault code blink patterns for this platform.

Most Replaced Parts on the G26Q3-75-3

Hot Surface Igniter for the G26Q3-75-3

Testing resistance at room temperature with power off confirms failure in under two minutes. An infinite ohm reading means the element is open-circuit and must be replaced before any heating cycle can complete.

G26Q3-75-3 Flame Sensor

Annual cleaning with fine steel wool extends sensor service life and prevents most early-season nuisance lockouts.

Draft Inducer Motor for the G26Q3-75-3

{‘Bearing failure presents as grinding during the pre-purge phase at startup and should be replaced before complete seizure.’ if not condensing else ‘The condensing-rated inducer must tolerate moisture from condensate-laden flue gases and must not be substituted with a standard 80% AFUE inducer. Bearing failure presents as grinding during the pre-purge phase.’}

G26Q3-75-3 Control Board

Read and document the two-digit LED blink code before ordering any replacement. The blink code directs the diagnosis to the specific failed component.

Why Choose Repair Clinic for G26Q3-75-3 Parts

  • Genuine Lennox OEM Components: Igniters, flame sensors, and inducers confirmed for the G26Q3-75-3 75000 BTU platform Lennox furnace parts.
  • Fault Code Diagnostic Resources: The Lennox furnace troubleshooting LED blink code chart is available alongside every part listing.
  • Non-Condensing B-Vent Context: The furnace uses standard metal B-vent, produces no condensate, and has a straightforward non-condensing service profile.
  • 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.

G26Q3-75-3 Furnace Parts FAQ

What is the BTU output and efficiency of the G26Q3-75-3?

The G26Q3-75-3 is a 75000 BTU input, 80% AFUE gas furnace from Lennox. The furnace uses standard metal B-vent, produces no condensate, and has a straightforward non-condensing service profile.

What type of venting does the G26Q3-75-3 require?

Standard metal B-vent. It produces no condensate and does not use PVC plastic venting.

My G26Q3-75-3 ignites and shuts off within seconds. What is wrong?

This is the flame sensor symptom. The sensor rod has oxidized and cannot pass adequate micro-amp current to confirm sustained combustion. Annual cleaning with fine steel wool prevents most occurrences.

How does the Lennox G26Q3-75-3 relate to the G26 series?

The G26Q3-75-3 is part of the Lennox G26 series of 80% AFUE non-condensing upflow furnaces. The Q3 identifies the cabinet configuration and 75 identifies 75,000 BTU capacity within the G26 series.

Lennox G26Q3-75-3 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Lennox G26Q3-75-3 problems ― and their solutions. Do any of these look familiar?
Furnace not heating
28 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
9 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
13 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Run Capacitor
Blower Motor
Igniter
Control Board