Shipping all 7 days! Hold times are long. Already ordered? Email [email protected]Learn more

Lennox Condensing Unit Contactor Replacement #10F73

03:09
27k
70
This video provides step-by-step repair instructions for replacing the contactor on a Lennox A/C condensing unit. The most common reason for replacing the contactor is the central air conditioner does not cool or is not running at all.

All of the information for this contactor replacement video is applicable to the following brands: Lennox

Tools used: quarter inch socket

Step By Step Instructions

1
To replace the contactor in your central air condensing unit first shut off the power to the unit.
2
You can do this by removing the fuses from the disconnect box or switching off the circuit breaker.
3
Use a quarter inch socket or nut driver to unthread the two bottom screws securing the access panel.
4
Pull the panel down to remove.
5
To ensure the run capacitor is discharged, place a screwdriver with an insulated handle across both sets of terminals – avoid touching the screwdriver blade.
6
Note the location of the wires connected to the old contactor – then disconnect them.
7
Unthread the mounting screws to release the old contactor.
8
Install the new contactor by positioning it on the housing then replace the mounting screws to secure.
9
Connect the wires to the appropriate terminals on the new contactor.
10
Slide the upper edge of the access panel under the top cover then thread and tighten the screws to secure.
11
With the repair completed, restore power to the condensing unit and your central air system should be ready for use.
Description
This video provides step-by-step repair instructions for replacing the contactor on a Lennox A/C condensing unit. The most common reason for replacing the contactor is the central air conditioner does not cool or is not running at all.

All of the information for this contactor replacement video is applicable to the following brands: Lennox

Tools used: quarter inch socket
Step-By-Step Instructions
1
To replace the contactor in your central air condensing unit first shut off the power to the unit.
2
You can do this by removing the fuses from the disconnect box or switching off the circuit breaker.
3
Use a quarter inch socket or nut driver to unthread the two bottom screws securing the access panel.
4
Pull the panel down to remove.
5
To ensure the run capacitor is discharged, place a screwdriver with an insulated handle across both sets of terminals – avoid touching the screwdriver blade.
6
Note the location of the wires connected to the old contactor – then disconnect them.
7
Unthread the mounting screws to release the old contactor.
8
Install the new contactor by positioning it on the housing then replace the mounting screws to secure.
9
Connect the wires to the appropriate terminals on the new contactor.
10
Slide the upper edge of the access panel under the top cover then thread and tighten the screws to secure.
11
With the repair completed, restore power to the condensing unit and your central air system should be ready for use.